Application Notes for: Microwave Phase Shifters, IQ Vector Modulators & Frequency Translators
The new Series 73/74 represents the latest addition to Kratos General Microwave’s existing line of PIN Diode I.Q. Vector Modulators. Their performance has been enhanced to provide a higher dynamic range of attenuation for today’s more demanding system applications. All models incorporate multiple bi-phase modulator sections to provide in excess of 60 dB attenuation range at any frequency. All models are also capable of a full 360° range of phase shift. The series covers a frequency range of 2 GHz to 24 GHz in three bands: 2 GHz to 6 GHz, 6 GHz to 18 GHz, and 16 GHz to 24 GHz. A simplified block diagram is shown in Fig. 1.
- Simultaneous control of amplitude and phase over a 50 dB dynamic range
- 2 to 24 GHz in three bands:
- 2 to 6 GHz
- 6 to 18 GHz
- 16 to 24 GHz
- 12 Bit digitally programmable (Series 73)
- Analog control (Series 74)
- High speed
- Guaranteed monotonicity
THEORY OF OPERATION
The block diagram of the I-Q Vector Modulator is shown in Figure 1. An RF signal incident on a 3 dB quadrature hybrid is divided into two equal outputs, with a 90° phase difference between them. The in-phase, or 0°, channel is designated the I channel and the Quadrature, or 90°, channel is designated the Q channel. Each signal passes through a biphase modulator which sets the 0° or 180° state and the attenuation level for both the I and Q paths. The outputs of the I and Q path are combined to yield the resultant vector which may fall anywhere within the bounded area shown in Figure 2. Any signal applied to the I-Q Vector Modulator can be shifted in phase and adjusted in amplitude by applying the following relationships:
- Let the desired attenuation level = X dB and the desired phase shift = θ° (with respect to 0 dB and 0° reference states).
- The normalized output voltage magnitude is given by: ? V ? = 10?(x/20).
- The values of the I and Q attenuator control inputs are then expressed as:
Figure 3 shows the nominal value of I and Q vs. either digital word (Series 73) or analog voltage (Series 74). Thus, to achieve an attenuation level of 3 dB with a phase offset of 112.5° (with respect to 0 dB and 0° reference states) the values of I and Q can be calculated as follows:
I = 0.707 cos (112.5°) =–0.027
Q = 0.707 sin (112.5°) =+0.65
From Figure 3, the control inputs to yield the desired amplitude and phase are approximately:
| Analog Units (72 Series) | Digital Units (71 Series) |
|---|---|
| I = 5.78 volts | 100101000000 |
| Q = 2.84 volts | 010010001011 |
While these values for I and Q will yield an output signal whose amplitude and phase are close to the nominal values over the entire operating frequency range of the vector modulator, the use of an iterative measurement procedure will determine the I and Q inputs which exactly define the desired parameter at any selected frequency.

| MODEL | 7322/7422 | 7328/7428 | 7329/7429 |
| Frequency | 2.0-6.0 GHz | 6.0-18.0 GHz | 16.0-24.0 GHz |
| Insertion Loss (max) | 16 dB | 20 dB 6-16 GHz 23 dB > 16-18 GHz |
21 dB |
| VSWR (max) | 1.8:1 | 2.3:1 | 2.5:1 |
| Power Handling Without Performance Degredation |
+20 dBm
|
||
| Survival Power (max) |
1W
|
||
| Absolute Insertion Phase Accuracy vs. Frequency (max) |
±25°
|
± 22°
|
|
| Variation of Phase vs. Temperature (max) |
± 0.2 deg./ °C
|
||
| Attenuation Range (min) |
50 dB
|
||
| Variation of Amplitude vs. Temperature (max) |
0.04dB/ °C
|
||
| Response Time (max) |
1.0 µsec
|
||
| Power Supply |
-12 to -15V @ 100 mA
+12 to +15V @ 100 mA |
||
| Control Input 73 Series 74 Series |
12 bit TTL for both I and Q inputs
0 to +10V DC for both I and Q inputs |
||
| Control Input Impedance 73 Series 74 Series |
40 µA max
10 K ohms |
||
| -54°C to + 100°C |
| -65° to + 125° C |
| MIL-STD-202F, Method 103B,Cond. B (96 hrs at 95%) |
| MIL-STD-202F, Method 213B, Cond. B (75 G, 6 msec) |
| MIL-STD-202F, Method 213B, Cond. B (75 G, 6 msec) |
| MIL-STD-202F, Method 204D,Cond. B (.06″ double amplitude or 15G, whichever is less |
| MIL-STD-202F, Method 105CCond. B (50,000 ft.) |
| MIL-STD-202F, Method 107DCond. A, 5 cycles |
| Mating power/control connector (Series 73 only) |
| Option no. | Description |
| 7 | Two SMA male RF connectors |
| 10 | One SMA male (J2) and one SMA female (J1) RF connector |
| G09 | Guaranteed to meet Environmental Ratings |
| G12 | RoHS Compliant |
| G18 | REACH Compliant |

| MODEL | A | B | C | D | E | F | G | H | J | K |
| 7322 | 4.00 ± .03(101,6) | 3.00±.03(76,2) | .88(22,4) | 3.80±.01(96,5) | 2.75± .01(69,9) | 1.50(38,1) | 1.90(48,3) | 2.00(50,8) | .68(17,3) | .10(2,9) |
| 7328 | 3.12 ± .03(79,2) | 3.00 ± .03(76,2) | .88(22,4) | 2.92 ± .01(74,2) | 2.75 ± .01(69,9) | 1.50(38,1) | 1.82(46,2) | 1.56(39,6) | .68(17,3) | .10(2,9) |
| 7329 | 3.25 ± .03(82,6) | 3.00 ± .03(76,2) | .82(20,8) | 3.00 ± .01(76,2) | 2.75 ± .01(69,9) | 1.50(38,1) | 1.69(42,9) | 1.62(41,1) | .65(16,5) | .12(3,0) |
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||